PRODUCT IMAGES
PRODUCT DESCRIPTION
TDS Pen Specifications
TDS | Conductivity | Temperature | ||||
Range | 0.00-14.00 | 0-19990ppm | 0-19990 μS/cm 0.001-20.00mS/cm | 0.1°C-60.0°C 32.0-140.0 ℉ | ||
Resolution | 0.01 | <9999ppm | 1ppm | <9999 μS/cm | 1 μS/cm | 0.1℃ 0.1 ℉ |
>9999ppm | *10ppm | >9999 μS/cm | *10μS/cm | |||
Precision | +/-0.01 | +/-2% | +/-2% | 0.5℃ | ||
Calibration | 6.86&4.00& 9.18 Three points automatic calibration | 1413 μS/cm | 1413μS/cm | |||
Temp Compensation | ATC :0-60℃ | |||||
Invirenment | 0---60°C RH:100% | |||||
Auto shut off | 5 Minutes | |||||
Battery | 3 *1.5 V ( LR44 button cell) | |||||
Size | 183*37*37mm | |||||
Weight | 80g |
Operation Steps
1.Remove the protective cap.
2.Clean the Electrode with distilled water and wipe clean the spare water.
3.Press the "ON/OFF" button .Turn on the meter.
4.Immerse the electrode in the solution
5. Lightly shake the meter, read the data when the numeric stabilized.
The temperate displays at the bottom of the screen .
6.Press “MODE”button to convert different mode .
7.Press the "ON/OFF" button to shut off the instrument .
Clean the electrode with pure water , cover the electrode protective cap
Exhibition
Our Advantage
Our Factory
Advanced production equipment | Professional and technical personnel |
Adequate product inventory | Rich industry experience |
PRODUCT IMAGES
PRODUCT DESCRIPTION
TDS Pen Specifications
TDS | Conductivity | Temperature | ||||
Range | 0.00-14.00 | 0-19990ppm | 0-19990 μS/cm 0.001-20.00mS/cm | 0.1°C-60.0°C 32.0-140.0 ℉ | ||
Resolution | 0.01 | <9999ppm | 1ppm | <9999 μS/cm | 1 μS/cm | 0.1℃ 0.1 ℉ |
>9999ppm | *10ppm | >9999 μS/cm | *10μS/cm | |||
Precision | +/-0.01 | +/-2% | +/-2% | 0.5℃ | ||
Calibration | 6.86&4.00& 9.18 Three points automatic calibration | 1413 μS/cm | 1413μS/cm | |||
Temp Compensation | ATC :0-60℃ | |||||
Invirenment | 0---60°C RH:100% | |||||
Auto shut off | 5 Minutes | |||||
Battery | 3 *1.5 V ( LR44 button cell) | |||||
Size | 183*37*37mm | |||||
Weight | 80g |
Operation Steps
1.Remove the protective cap.
2.Clean the Electrode with distilled water and wipe clean the spare water.
3.Press the "ON/OFF" button .Turn on the meter.
4.Immerse the electrode in the solution
5. Lightly shake the meter, read the data when the numeric stabilized.
The temperate displays at the bottom of the screen .
6.Press “MODE”button to convert different mode .
7.Press the "ON/OFF" button to shut off the instrument .
Clean the electrode with pure water , cover the electrode protective cap
Exhibition
Our Advantage
Our Factory
Advanced production equipment | Professional and technical personnel |
Adequate product inventory | Rich industry experience |